Flow monitors

SI1006

SID10ADBFKOW/LS 
Compact type for adapter 
Quick disconnect 
 
1 relay output
 
 Application liquids and gases
 Electrical design AC / relay
 Output normally open / closed programmable
Nominal voltage [V] 90...240 AC (45...65 Hz)
Operating voltage [V]  85...265 AC
Voltage tolerance [%]  -5 / +10
Contact rating 3 A (250 V AC / 30 V DC) *)
Power consumption [VA]  < 3.5
Max. temperature gradient of medium [K/min]  300
Pressure rating [bar]  300
Liquids
Medium temperature [°C] 
-25...80
Setting range [cm/s] 3...300
Greatest sensitivity [cm/s]  3...60
Gases
Medium temperature [°C] 
-25...80
Setting range [cm/s]  200...3000
Greatest sensitivity [cm/s]  200...800
Adjustment of the switch point pushbuttons
Power-on delay time [s]  15 **)
Response time [s]  1...10
Operating temperature [°C]  -25...80
Protection IP 67
Shock resistance [g] 50 (DIN / IEC 68-2-27, 11 ms)
Vibration resistance [g] 20 (DIN / IEC 68-2-6, 55-2000 Hz)
Housing material PBT-GF 20
Sensor material stainless steel (316S12); O-ring: FPM 8 x 1.5 gr 80° Shore A
Function display
Function LED
 
10 LEDs, three-colour
Connection 1/2" UNF-Connector
Wiring

N.B: no protective insulation between relay circuit and supply voltage
Remarks n.c. = not connected
*) number of switching cycles: 20 million mechanically
switching cycles with 3 A load: 100.000 electrically
relay type: contact closed at work
**) optically indicated
efector, inc., 805 Springdale Dr., Exton, PA 19341 —  We reserve the right to make technical alterations without prior notice.   —   US  -  SI1006   —   14.12.2004